6AG2193-6BP20-4BF0

SIPLUS ET 200SP BU type F0 BaseUnit with conformal coating, push-in terminals, 4 AUX terminals, and 20 mm width. Request a model-specific quote.

Product Code
6AG2193-6BP20-4BF0
Dimensions
12.2 × 4.5 × 2.8 cm
Weight
0.057 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Product type BU type F0
Base product 6ES7193-6BP20-0BF0
Terminals Push-in terminals
AUX terminals 4, bridged to the left
Current carrying capacity, up to 60 °C 10 A
Current carrying capacity, for process terminals 5 A
Ambient temperature during operation, horizontal installation -40 °C to 70 °C; +85 °C for 10 min (OT4, ST1/ST2 according to EN 50155)
Ambient temperature during operation, vertical installation -40 °C to 50 °C
Potential separation Between the backplane bus, process terminals, and power bus and the supply voltage

Key Features

  1. BU type F0: Product type designation: BU type F0, with 1 slot.
  2. Push-in terminals and AUX terminals: Has push-in terminals and 4 AUX terminals bridged to the left.
  3. Current carrying capacity: Current carrying capacity is up to 10 A at up to 60 °C, 10 A for the P1 and P2 bus, 10 A for the AUX bus, and 5 A for process terminals.
  4. Electrical isolation: Has potential separation between the backplane bus, process terminals, and power bus and the supply voltage.
  5. Conformal coating: Has conformal coating with Class 2 for high reliability according to EN 61086 and Type 1 protection against fouling according to EN 60664-3.
  6. Railway environmental performance: Supports railway applications according to EN 50121-3-2, EN 50121-4, EN 50121-5, EN 50124-1, EN 50125-1, EN 50125-2, EN 50125-3, EN 50155, and EN 61373.

Frequently Asked Questions

1. What type of BaseUnit is Siemens 6AG2193-6BP20-4BF0?

It is a BU type F0 BaseUnit with 1 slot, based on 6ES7193-6BP20-0BF0.

2. How many AUX terminals does this BaseUnit have?

It has 4 AUX terminals bridged to the left.

3. What current carrying capacity does it have for process terminals?

The maximum current carrying capacity for process terminals is 5 A.

4. What are the operating temperature limits for horizontal installation?

For horizontal installation, the ambient temperature during operation is -40 °C to 70 °C, with +85 °C for 10 min (OT4, ST1/ST2 according to EN 50155).

5. Does it include a system-integrated shield connection?

The system-integrated shield connection is optional.

Send Inquiry