6AG1210-1PE26-2UL0

SIPLUS PM240-2 FSD 30 kW converter with integrated braking chopper, IP20 protection, 380-480 V 3 AC input, and -20…+50 °C range. Request a model-specific quote.

Product Code
6AG1210-1PE26-2UL0
Dimensions
49.5 × 35.6 × 30 cm
Weight
18.3 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Product type PM240-2
Product version FSD 30 kW
Input 380-480 V 3 AC +10/-20 %, 47-63 Hz
Integrated function Braking chopper
Low-overload active power 30 kW
High-overload active power 22 kW
Maximum output current 90 A
Pulse frequency 4 kHz
Cooling Internal air cooling
Protection IP20

Key Features

  1. Converter type and design: Product type designation: PM240-2; product version: FSD 30 kW; converter design: FSD.
  2. Input and braking: Input: 380-480 V 3 AC +10/-20 %, 47-63 Hz; integrated braking chopper; mains filter: No.
  3. Overload power: Low overload: 30 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload: 22 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
  4. Output and pulse frequency: Maximum output current: 90 A; output current without overload and with low overload: 60 A; with high overload: 45 A; pulse frequency: 4 kHz.
  5. Protection and cooling: IP20 protection with undervoltage, overvoltage, overload, ground-fault, short-circuit, stall, blocked-rotor, motor-temperature, and converter-temperature protection. Cooling: internal air cooling.
  6. Form factor and delivery: FSF design; dimensions: 472 x 200 x 237 (H x W x D); supplied without CU and operating unit.

Frequently Asked Questions

1. What is the product type and version?

It has product type designation PM240-2 and product version FSD 30 kW.

2. What input supply does it use?

Input is 380-480 V 3 AC +10/-20 %, 47-63 Hz.

3. What overload power ratings are provided?

Low overload is 30 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload is 22 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.

4. What protection and cooling details should be checked?

It has IP20 protection and internal air cooling, with multiple protection functions including overload, ground-fault, short-circuit, and temperature protection.

5. What is included in the delivery configuration?

It is supplied without CU and operating unit.

Send Inquiry