6AG1210-1PE14-2UL1

Siemens 6AG1210-1PE14-2UL1 SIPLUS G120 PM240-2 converter with 1.5 kW low-overload power, IP20 protection, and integrated braking chopper. Request a model-specific quote.

Product Code
6AG1210-1PE14-2UL1
Dimensions
16.5 × 7.3 × 19.6 cm
Weight
1.622 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Product type PM240-2
Design FSA
Low-overload power 1.5 kW
High-overload power 1.1 kW
Input 380-480 V 3 AC +10/-10%, 47-63 Hz
Maximum output current 6.2 A
Output voltage 0% to 95% of input voltage
Pulse frequency 4 kHz
Integrated braking chopper Yes
Cooling Internal air cooling, 0.005 m3/s

Key Features

  1. Power and overload ratings: Low overload: 1.5 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload: 1.1 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
  2. Input and output: Input: 380-480 V 3 AC +10/-10%, 47-63 Hz. Maximum output current: 6.2 A; output voltage: 0% to 95% of input voltage.
  3. Braking and coating: The converter has an integrated braking chopper and conformal coating. The mains filter is not present.
  4. Protection and monitoring: Protection includes undervoltage, overvoltage, overload, ground-fault, short-circuit, and stall protection, plus motor and converter temperature monitoring.
  5. Cooling and installation: Internal air cooling with 0.005 m3/s cooling air flow. Dimensions are 196 x 73 x 165 mm (H x W x D); degree of protection is IP20.
  6. Firmware release condition: Released as of CU FW version V4.7 HF8. The product lifecycle is Active Product.

Frequently Asked Questions

1. What type of converter is Siemens 6AG1210-1PE14-2UL1?

It is a SIPLUS G120 PM240-2 converter with FSA design, based on 6SL3210-1PE14-3UL1.

2. What are the low- and high-overload power ratings?

Low overload is 1.5 kW; high overload is 1.1 kW. The specified overload durations and cycle times apply: 3 s and 57 s within a 300 s cycle.

3. What are the input, cooling, and protection details?

Input is 380-480 V 3 AC +10/-10% at 47-63 Hz. Cooling is internal air cooling at 0.005 m3/s, and protection is IP20.

Send Inquiry