Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Product type | PM240-2 |
| Product version | FSA 3 kW |
| Low-overload power | 3 kW |
| High-overload power | 2.2 kW |
| Input supply | 380–480 V 3 AC +10/-10%, 47–63 Hz |
| Maximum output current | 11.8 A |
| Output voltage | 0% to 95% of input voltage |
| Pulse frequency | 4 kHz |
| Cooling method | Internal air cooling |
| Protection degree | IP20 |
Key Features
- Power and overload ratings: Low overload: 3 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload: 2.2 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
- Input supply: Input: 380–480 V 3 AC +10/-10%, 47–63 Hz. Input voltage type: AC; mains filter: not present.
- Output current and voltage: Maximum output current: 11.8 A; output current without overload: 7.7 A; output voltage: 0% to 95% of input voltage.
- Integrated braking chopper: The converter has an integrated braking chopper and a 4 kHz pulse frequency.
- Cooling, protection, and installation: Internal air cooling with 0.005 m3/s cooling air flow, IP20 protection, FSA design, and dimensions of 196 x 73 x 165 mm (H x W x D).
- Protective functions: Undervoltage, overvoltage, overload, ground-fault, short-circuit, stall, blocked-rotor, motor-temperature, and converter-temperature protection are provided, with parameter locking.
Frequently Asked Questions
1. What is the low-overload power of Siemens 6AG1210-1PE18-2UL1?
Low-overload power is 3 kW: 150% for 3 s, 110% for 57 s, and 100% for 240 s.
2. What input supply does the PM240-2 converter use?
The input is 380–480 V 3 AC +10/-10% at 47–63 Hz. The mains filter is not present.
3. What protection and cooling details should be checked before inquiry?
The converter has IP20 protection and internal air cooling with 0.005 m3/s cooling air flow. Confirm the FSA design and 196 x 73 x 165 mm (H x W x D) dimensions.