Technical Summary
| Parameter | Value |
|---|---|
| Product type | KTP400F Mobile |
| Display | 4.3 in TFT widescreen display |
| Resolution | 480 pixel horizontal × 272 pixel vertical |
| Function keys | 4 function keys with LEDs |
| Direct keys | 32 touch buttons as S7 input I/O |
| Supply | 24 V DC |
| Supply range | 19.2 V to 28.8 V |
| Interfaces | 1 PROFINET interface; 1 USB 2.0 interface |
| Protocols | PROFINET IO, PROFIsafe, EtherNet/IP, MODBUS |
| Protection | IP65 all-round |
Applications
- Operator acknowledgement: The integrated acknowledgement button supports operator acknowledgement.
- Emergency stop operation: The emergency stop button supports emergency-stop operation.
- HMI touch and key operation: The panel supports operator interaction through touch and key operation.
Key Features
- Mobile HMI operation: SIMATIC HMI KTP400F Mobile provides touch and key operation with a 4.3 in widescreen TFT display.
- Function keys and keyboard: It has 4 function keys with LEDs, plus numeric and alphanumeric onscreen keyboards.
- Safety controls: The panel has an emergency stop button with illuminated and forced blocking, a 3-stage acknowledgement button, and a stop button with forced blocking.
- PROFINET communication: It has 1 industrial Ethernet interface and 1 PROFINET interface, and supports PROFINET IO, PROFIsafe, EtherNet/IP, and MODBUS.
- Power and connection: The supply is 24 V DC with a permissible range of 19.2 V to 28.8 V; 1 USB 2.0 interface is provided.
- Protection and diagnostics: IP65 all-round protection and readable diagnostic information are supplied.
Frequently Asked Questions
1. What type of display does the 6AV2125-2DB23-0AX0 have?
It has a 4.3 in widescreen TFT color display with 480 pixel horizontal resolution and 272 pixel vertical resolution.
2. Which communication interfaces and protocols are supported?
It has 1 industrial Ethernet interface, 1 PROFINET interface, and 1 USB 2.0 interface. Supported protocols include PROFINET IO, PROFIsafe, EtherNet/IP, TCP/IP, DHCP, SNMP, DCP, LLDP, and MODBUS.
3. What supply voltage does the panel require?
The supply is 24 V DC, with a permissible range of 19.2 V to 28.8 V.
4. Which safety and acknowledgement controls are included?
It has an illuminated emergency stop button with forced blocking, a 3-stage acknowledgement button, and a stop button with forced blocking.