Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Input phases | 3 AC |
| Line voltage | 380 … 480 V +10 % -20 % |
| Line frequency | 47 … 63 Hz |
| Rated output power, LO | 18.50 kW | 25.00 hp |
| Rated output power, HO | 15.00 kW | 20.00 hp |
| Digital inputs | 6 standard digital inputs; 1 fail-safe digital input |
| Analog input | 1 differential input, 10 bit |
| Communication | PROFIBUS DP |
| Protection | IP20 / UL open type |
| Frame size | FSC |
Applications
- Motor control: Supports V/f control, V/f with flux current control, V/f ECO control, and sensorless vector control.
Key Features
- Rated output power: 18.50 kW | 25.00 hp at low overload (LO) and 15.00 kW | 20.00 hp at high overload (HO).
- I/O interface: 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, and 1 non-isolated analog output.
- Communication and safety: PROFIBUS DP communication and integrated Safe Torque Off.
- Input and output frequency: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output frequency: 0 … 240 Hz for vector control and 0 … 550 Hz for V/f control.
- Connection and protection: Plug-in screw terminals, IP20 / UL open type, FSC frame size, and dimensions of 140 mm width × 203 mm depth.
Frequently Asked Questions
1. What output power does the 6SL3210-1KE23-8AP1 provide?
It provides 18.50 kW | 25.00 hp at low overload (LO) and 15.00 kW | 20.00 hp at high overload (HO).
2. How many I/O points does this converter have?
It has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, and 1 non-isolated analog output.
3. Which communication interface is provided?
The converter provides PROFIBUS DP communication.
4. What connections and protection are available?
It has plug-in screw terminals and IP20 / UL open type protection. Verify the required conductor cross-sections and installation details before inquiry.