Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Input voltage | 380 … 480 V +10 % -20 % |
| Input frequency | 47 … 63 Hz |
| Rated power (LO) | 1.10 kW | 1.50 hp |
| Rated power (HO) | 0.75 kW | 1.00 hp |
| Standard digital inputs | 6 |
| Fail-safe digital inputs | 1 |
| Digital outputs | 1 relay changeover contact; 1 transistor |
| Analog input | 1 differential input, 10 bit |
| Analog output | 1 non-isolated output |
| Communication | PROFIBUS DP |
| Protection | IP20 / UL open type |
Applications
- Drive control with V/f techniques: Supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), and V/f ECO linear / square-law control techniques.
- Sensorless vector drive control: Supports sensorless vector control.
Key Features
- Drive ratings: Rated power is 1.10 kW at low overload and 0.75 kW at high overload. Output is 3 AC with rated currents of 3.10 A (LO) and 2.20 A (HO).
- I/O configuration: The unfiltered external 24V I/O interface has 6 standard digital inputs, 1 fail-safe digital input, 2 digital outputs, 1 differential analog input, and 1 non-isolated analog output.
- PROFIBUS DP interface: Communication is provided through PROFIBUS DP.
- Control techniques: Supported techniques include V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
- Connections and motor cable: Line, motor-end, and DC-link connections use plug-in screw terminals. Maximum shielded motor cable length is 150 m (492.13 ft).
- Protection and frame size: The converter has IP20 / UL open type protection and frame size FSAA. Dimensions are 73 mm (2.87 in) wide and 155 mm (6.10 in) deep.
Frequently Asked Questions
1. What is the rated power of Siemens 6SL3210-1KE13-2UP2?
Rated power is 1.10 kW | 1.50 hp at low overload and 0.75 kW | 1.00 hp at high overload.
2. How many digital inputs and outputs does this converter have?
It has 6 standard digital inputs, 1 fail-safe digital input, and 2 digital outputs: 1 relay changeover contact and 1 transistor.
3. Which communication interface is supported?
The converter supports PROFIBUS DP.
4. What analog I/O is included?
It has 1 differential analog input with 10-bit resolution and 1 non-isolated analog output.
5. What should be verified before requesting a quote?
Verify the 3AC 380 … 480 V +10 % -20 % input, PROFIBUS DP communication, plug-in screw terminals, FSAA frame size, and IP20 / UL open type protection.