6SL3210-1KE12-3UB2

Siemens 6SL3210-1KE12-3UB2 SINAMICS G120C drive with 6DI, 2DO, 1AI, 1AO and Safe Torque Off. USS/MODBUS RTU, IP20, and 0.75 kW LO rating. Request a model-specific quote.

Product Code
6SL3210-1KE12-3UB2
Dimensions
22.5 × 27 × 8.5 cm
Weight
1.1 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Input phases 3 AC
Line voltage 380 … 480 V +10 % -20 %
Low-overload rated power 0.75 kW | 1.00 hp
High-overload rated power 0.55 kW | 0.75 hp
Standard digital inputs 6
Fail-safe digital inputs 1
Communication USS/MODBUS RTU
Output frequency for vector control 0 … 240 Hz
Output frequency for V/f control 0 … 550 Hz
Frame size FSAA
Degree of protection IP20 / UL open type

Key Features

  1. Low-overload rated power: Rated power is 0.75 kW | 1.00 hp at low overload and 0.55 kW | 0.75 hp at high overload.
  2. I/O configuration: The drive has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential input, and 1 non-isolated analog output.
  3. Communication: Communication uses USS/MODBUS RTU.
  4. Control techniques: Supported techniques include V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
  5. Connections and protection: It has plug-in screw terminals, IP20 / UL open type protection, and an FSAA frame size.

Frequently Asked Questions

1. What is the rated power of the 6SL3210-1KE12-3UB2?

It has a rated power of 0.75 kW | 1.00 hp at low overload and 0.55 kW | 0.75 hp at high overload.

2. Which I/O does this drive provide?

It provides 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential input, and 1 non-isolated analog output.

3. Which communication protocol is supported?

Communication uses USS/MODBUS RTU.

Send Inquiry