6SL3210-1KE11-8AF2

Siemens 6SL3210-1KE11-8AF2 SINAMICS G120C drive with PROFINET, 6DI, 2DO, 1AI and 1AO. Request a model-specific module quote.

Product Code
6SL3210-1KE11-8AF2
Dimensions
22.5 × 27 × 8.5 cm
Weight
1.4 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Communication PROFINET, EtherNet/IP
Standard digital inputs 6
Fail-safe digital inputs 1
Analog input 1 differential input, 10 bit
Analog output 1 non-isolated output
Rated power (LO) 0.55 kW | 0.75 hp
Rated power (HO) 0.37 kW | 0.50 hp
Input voltage 3 AC, 380 … 480 V +10 % -20 %
Line frequency 47 … 63 Hz
Output frequency for vector control 0 … 240 Hz
Degree of protection IP20 / UL open type
Frame size FSAA

Key Features

  1. Communication interfaces: Communication: PROFINET, EtherNet/IP.
  2. I/O configuration: The I/O interface has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input and 1 non-isolated analog output.
  3. Rated output power: Rated power: 0.55 kW | 0.75 hp (LO); 0.37 kW | 0.50 hp (HO).
  4. Input supply: Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz.
  5. Connection and installation: Line-side, motor-end and DC-link connections use plug-in screw terminals. Frame size: FSAA; dimensions: 73 mm width and 160 mm depth.
  6. Protection and cooling: Degree of protection: IP20 / UL open type. Cooling uses an integrated fan.

Frequently Asked Questions

1. What communication protocols does the 6SL3210-1KE11-8AF2 support?

It supports PROFINET and EtherNet/IP communication.

2. How many I/O channels does this SINAMICS G120C variant provide?

It has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input and 1 non-isolated analog output.

3. What are the LO and HO rated output powers?

Rated power is 0.55 kW | 0.75 hp for LO and 0.37 kW | 0.50 hp for HO.

4. What supply does the converter require?

The input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.

5. How is the 6SL3210-1KE11-8AF2 connected and protected?

Line-side, motor-end and DC-link connections use plug-in screw terminals. Protection is IP20 / UL open type, with cooling by an integrated fan.

Send Inquiry