Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Module type | SIPLUS S7-300 analog output spare part |
| Analog outputs | 8; 4 @ +70 °C |
| Output ranges, voltage | 0 to 10 V; 1 V to 5 V; -10 V to +10 V |
| Output ranges, current | 0 to 20 mA; -20 mA to +20 mA; 4 mA to 20 mA |
| Resolution with overrange | max. 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit |
| Conversion time | 0.8 ms per channel |
| Rated load voltage L+ | 24 V DC |
| Connection | 40-pole; four-wire for voltage output; two-wire for current output |
| Diagnostics | Diagnostics and diagnostic alarms: Yes; parameterizable |
| Potential separation | Between the channels and backplane bus: Yes; between the channels: No |
| Operating temperature | -25…+70 °C |
Applications
- Analog output control: Provides voltage and current outputs for connected actuators through four-wire voltage-output or two-wire current-output connections.
Key Features
- Analog output channels: 8 analog outputs; 4 @ +70 °C.
- Voltage and current ranges: Voltage: 0 to 10 V, 1 V to 5 V, and -10 V to +10 V. Current: 0 to 20 mA, -20 mA to +20 mA, and 4 mA to 20 mA.
- Resolution and conversion: Resolution with overrange: max. 12 bit; conversion time: 0.8 ms per channel.
- Diagnostics and alarms: Diagnostics, parameterizable substitute values, parameterizable diagnostic alarms, readable diagnostic information, and a red group error SF LED.
- Supply and protection: Rated load voltage L+: 24 V DC with reverse polarity protection. Voltage outputs have short-circuit protection; maximum short-circuit current is 25 mA.
- Connection and isolation: 40-pole connection; four-wire connection for voltage outputs and two-wire connection for current outputs. The analog outputs are isolated from the backplane bus and load voltage L+.
Frequently Asked Questions
1. How many analog outputs does the 6AG1332-5HF00-2AB0 have?
It has 8 analog outputs; 4 @ +70 °C.
2. Which voltage and current output ranges are supported?
Voltage ranges are 0 to 10 V, 1 V to 5 V, and -10 V to +10 V. Current ranges are 0 to 20 mA, -20 mA to +20 mA, and 4 mA to 20 mA.
3. What resolution and conversion time does it provide?
Resolution with overrange is max. 12 bit, and conversion time is 0.8 ms per channel.
4. What diagnostics are available?
Diagnostics, parameterizable substitute values, parameterizable diagnostic alarms, readable diagnostic information, and a red group error SF LED are available.
5. What connection and supply details should be verified before inquiry?
Verify the 40-pole connection, four-wire voltage-output or two-wire current-output connection, and the rated 24 V DC load voltage L+.