Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Product type | CPU 1215C DC/DC/DC |
| Digital inputs | 14 at 24 V DC |
| Digital outputs | 10 at 24 V DC, 0.5 A |
| Analog inputs | 2; 0 to 10 V DC |
| Analog outputs | 2; 0 to 20 mA DC |
| PROFINET ports | 2 RJ 45 Ethernet ports |
| PROFINET transmission rate, max. | 100 Mbit/s |
| Supply | 20.4 V to 28.8 V DC |
| Work memory | 125 kbyte |
| Load memory | 4 Mbyte |
| Protection | IP20 |
| Coating | Conformal coating |
Applications
- Digital signal acquisition: Acquires digital signals through 14 integrated digital inputs at 24 V DC.
- Analog signal acquisition and output: Acquires 0 to 10 V signals through 2 analog inputs and provides 0 to 20 mA signals through 2 analog outputs.
- PROFINET communication: Operates as a PROFINET IO Controller or PROFINET IO device through its 2 PROFINET ports.
- Positioning control: Supports controlled positioning, with up to 8 position-controlled positioning axes and 4 positioning axes via pulse-direction interface.
Key Features
- Integrated I/O: 14 digital inputs at 24 V DC, 10 digital outputs at 24 V DC and 0.5 A, 2 analog inputs at 0 to 10 V DC, and 2 analog outputs at 0 to 20 mA DC.
- PROFINET interfaces: 2 RJ 45 Ethernet ports with an integrated switch; PROFINET transmission rate up to 100 Mbit/s.
- Communication protocols: Supports PROFINET IO Controller, PROFINET IO device, SIMATIC communication, OPC UA Server, MODBUS, TCP/IP, UDP, and SNMP.
- Supply and memory: DC supply range: 20.4 V to 28.8 V DC. Integrated work memory: 125 kbyte; integrated load memory: 4 Mbyte.
- Technology functions: 6 digital inputs support HSC functions, 4 outputs support 100 kHz Pulse Train Output, and 6 counters support counting up to 100 kHz.
- Protection and coating: Conformal coating and IP20 protection; reverse polarity protection is available.
Frequently Asked Questions
1. What I/O does Siemens 6AG1215-1AG40-4XB0 provide?
It has 14 digital inputs at 24 V DC, 10 digital outputs at 24 V DC and 0.5 A, 2 analog inputs at 0 to 10 V DC, and 2 analog outputs at 0 to 20 mA DC.
2. How many PROFINET ports are available?
It has 2 RJ 45 Ethernet ports with an integrated switch and a maximum PROFINET transmission rate of 100 Mbit/s.
3. What supply voltage does the CPU require?
The DC supply permissible range is 20.4 V to 28.8 V DC.
4. Does the CPU support OPC UA?
Yes. It supports an OPC UA Server; a "Basic" runtime license is required.
5. What protection and coating does this configuration have?
It has conformal coating and IP20 protection.