Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Product type | CPU 1215FC DC/DC/DC |
| Supply | DC 20.4 to 28.8 V DC |
| Digital inputs | 14 DI, 24 V DC |
| Digital outputs | 10 DQ, 24 V DC, 0.5 A |
| Analog inputs | 2 AI, 0 to +10 V |
| Analog outputs | 2 AQ, 0 to 20 mA |
| PROFINET ports | 2 RJ 45 ports, up to 100 Mbit/s |
| Load memory | 4 Mbyte integrated |
| Communication protocols | PROFINET IO Controller, PROFINET IO device, PROFIsafe, OPC UA, TCP/IP, UDP, MODBUS and S7 communication |
| Protection | IP20 |
| Temperature specification | -25…+55 °C |
| Conformal coating | Yes |
Applications
- PROFINET IO control: Can act as a PROFINET IO Controller or PROFINET IO device for PROFINET communication.
- S7 communication: Supports S7 communication as a server and as a client.
- Open Ethernet communication: Supports TCP/IP, ISO-on-TCP (RFC1006) and UDP for Open IE communication.
- Web and OPC UA communication: Provides a web server and OPC UA Server functions, including data access, subscriptions and method calls; a runtime license is required for OPC UA.
Key Features
- Integrated digital I/O: Has 14 digital inputs at 24 V DC and 10 digital outputs at 24 V DC, with 0.5 A rated output current.
- Integrated analog I/O: Has 2 analog inputs with a 0 to +10 V range and 2 analog outputs with a 0 to 20 mA range.
- PROFINET interfaces: Provides 2 RJ 45 ports through 1 PROFINET interface, with an integrated switch and transmission rate up to 100 Mbit/s.
- Communication protocols: Supports PROFINET IO Controller, PROFINET IO device, PROFIsafe, OPC UA Server, TCP/IP, UDP, MODBUS and S7 communication.
- Supply and memory: Uses DC 20.4 to 28.8 V DC supply, has 4 Mbyte integrated load memory and 500 mA rated current consumption for the CPU only.
- Protection and diagnostics: Has IP20 protection, conformal coating, a diagnostic buffer, and RUN/STOP, ERROR and MAINT LEDs.
Frequently Asked Questions
1. What I/O is integrated in Siemens 6AG1215-1AF40-5XB0?
It has 14 digital inputs at 24 V DC, 10 digital outputs at 24 V DC with 0.5 A rated output current, 2 analog inputs from 0 to +10 V, and 2 analog outputs from 0 to 20 mA.
2. How many PROFINET ports does the CPU have?
It has 2 RJ 45 ports through 1 PROFINET interface, with an integrated switch and transmission rate up to 100 Mbit/s.
3. Which communication protocols are supported?
Supported protocols and services include PROFINET IO Controller, PROFINET IO device, PROFIsafe, OPC UA Server, TCP/IP, UDP, MODBUS and S7 communication.
4. What supply voltage is required?
The supply is DC 20.4 to 28.8 V DC; the rated value is 24 V DC.
5. What should be verified before requesting a quote?
Verify the required I/O ranges, PROFINET port configuration, communication protocols, OPC UA runtime-license requirement, supply voltage and installation conditions.