| Parameter | Value |
|---|---|
| Product type | CPU 1214C DC/DC/DC |
| Supply | 24 V DC; permissible range 20.4 V to 28.8 V DC |
| Digital inputs | 14; 6 usable for HSC functions |
| Digital outputs | 10; 4 high-speed outputs, 100 kHz Pulse Train Output |
| Analog inputs | 2; 0 to +10 V |
| PROFINET interfaces | 1; isolated; RJ 45 Ethernet, 1 port |
| Transmission rate, max. | 100 Mbit/s |
| Communication protocols | PROFINET IO Controller, PROFINET IO device, OPC UA Server, MODBUS, TCP/IP, PROFIBUS |
| Pulse outputs | 4; limit frequency 100 kHz |
| Position-controlled axes, max. | 8 |
| Protection | IP20; conformal coating |
Applications
- Digital signal acquisition: Acquires signals through 14 integrated digital inputs, including 6 inputs usable for HSC functions.
- Analog signal acquisition: Acquires voltage signals through 2 analog inputs with a 0 to +10 V input range.
- Pulse output and positioning: Provides 4 high-speed pulse outputs at up to 100 kHz and supports controlled positioning with up to 8 position-controlled axes.
- PID control: Supports PID controller functions.
Key Features
- Integrated I/O: Has 14 digital inputs, 10 digital outputs, and 2 analog inputs with 0 to +10 V input range; analog outputs: 0.
- DC supply: Rated supply is 24 V DC with a permissible range of 20.4 V to 28.8 V DC.
- PROFINET interface: Has 1 isolated PROFINET interface with an RJ 45 Ethernet connection and 1 port; transmission rate, max. 100 Mbit/s.
- Communication protocols: Supports PROFINET IO Controller, PROFINET IO device, SIMATIC communication, OPC UA Server, MODBUS, TCP/IP, and PROFIBUS with CM 1243-5 or CM 1242-5 required.
- Diagnostics and motion functions: Provides a diagnostic buffer, RUN/STOP, ERROR, and MAINT LEDs, 6 counters with counting frequency up to 100 kHz, and PID controller support.
- Protection and coating: Has conformal coating and IP20 degree of protection.
Frequently Asked Questions
1. What I/O does the 6AG1214-1AG40-2XB0 have?
It has 14 integrated digital inputs, 10 digital outputs, and 2 analog inputs. It has 0 analog outputs.
2. What supply voltage does this CPU use?
The rated supply is 24 V DC, with a permissible range of 20.4 V to 28.8 V DC.
3. Which network interface and protocols are supported?
It has 1 isolated PROFINET interface with an RJ 45 Ethernet connection and 1 port. It supports PROFINET IO, SIMATIC communication, OPC UA Server, MODBUS, TCP/IP, and PROFIBUS with CM 1243-5 or CM 1242-5 required.
4. What installation and environmental details should be verified before inquiry?
Verify the IP20 protection, conformal coating, -40…+70 °C range, and start up at -25 °C.