Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Rated output voltage | 24 V DC |
| Rated output current | 5 A |
| Input voltage at DC | 110 V |
| Input voltage range | 77 … 154 V DC |
| Adjustable output voltage | 24 … 28.8 V; max. 120 W |
| Output buffering time | 20 ms at Vin = 110 V |
| Protection class | IP20 |
| Connection | Screw terminal |
| Mounting | DIN rail EN 60715 35×7.5/15 |
| Operating temperature | -40 … +70 °C; +85 °C for 10 min at max. 4 A, horizontal installation |
Applications
- Railway power supply: The source identifies railway application in accordance with EN 50121-3-2, EN 50124-1, EN 50125-1, EN 50155, and EN 61373.
Key Features
- Input and output: Input: 110 V DC, with an input voltage range of 77 … 154 V. Output: 24 V DC rated value and 5 A rated value.
- Adjustable output: The output voltage is adjustable from 24 … 28.8 V via a potentiometer, with a maximum of 120 W.
- Output monitoring: A green LED indicates 24 V OK. The auxiliary signal uses a relay contact with a NO contact, rated 60 V DC/ 0.3 A.
- Protection and isolation: The output is short-circuit proof with shutdown and periodic restart attempts. Input and output have galvanic isolation; protection class is IP20.
- Connections and mounting: The unit uses screw terminals and snaps onto DIN rail EN 60715 35×7.5/15. Enclosure dimensions are 42 × 125 × 125 mm.
- Railway conditions: Horizontal operation is supported at -40 … +70 °C; +85 °C for 10 min at max. 4 A, with OT4/ST1/ST2 according to EN 50155.
Frequently Asked Questions
1. What input and output does the 6AG2333-0SB00-4AY0 have?
It has a 110 V DC input and a 24 V DC output with a 5 A rated value.
2. Can the output voltage be adjusted?
Yes. The output voltage is adjustable from 24 … 28.8 V via a potentiometer, with a maximum of 120 W.
3. How is the power supply mounted?
It snaps onto DIN rail EN 60715 35×7.5/15. DIN-rail mounting is supported; S7 rail mounting and wall mounting are not.
4. What connections are provided?
It uses screw terminals. Input, output, and ground each have 1 screw terminal for 0.2 … 2.5 mm2 single-core/finely stranded conductors.