| Parameter | Value |
|---|---|
| Input voltage | 120 V DC, 230 V DC, 120 V AC, and 230 V AC |
| Output voltage | DC |
| Backplane bus output, 5 V DC | 10 A max.; no base load required |
| Backplane bus output, 24 V DC | 1 A max.; idling-proof |
| Line frequency | 50 Hz or 60 Hz rated; permissible range 47 Hz to 63 Hz |
| Mains buffering | 20 ms stored energy time; according to NAMUR recommendation |
| Input power | 95 W active power input, typ. |
| Power loss | 20 W, typ. |
| Connection | 3x 1.5 mm2 solid or stranded wire with end sleeve |
| Protection | Short-circuit protection; equipment protection class I with protective conductor |
| Conformal coating | Class 2 for high reliability |
Applications
- Backplane bus power supply: Supplies the backplane bus with 5 V DC up to 10 A and 24 V DC up to 1 A.
- Mains failure buffering: Provides 20 ms stored energy time during mains or voltage failure.
Key Features
- Wide input range: Rated input values include 120 V DC, 230 V DC, 120 V AC, and 230 V AC.
- Backplane bus output: The DC output provides up to 10 A at 5 V DC for the backplane bus with no base load required, and up to 1 A at 24 V DC with idling-proof operation.
- Line frequency: Rated line frequency is 50 Hz or 60 Hz, with a permissible range from 47 Hz to 63 Hz.
- Mains buffering: Stored energy time during mains or voltage failure is 20 ms; mains buffering is according to NAMUR recommendation.
- Protection and coating: The power supply has short-circuit protection, equipment protection class I with protective conductor, and conformal coating for printed circuit board assemblies, Class 2 for high reliability.
- Connection and dimensions: The electrical connection uses 3x 1.5 mm2 solid or stranded wire with end sleeve. Dimensions are 50 mm wide, 290 mm high, and 217 mm deep; weight is approximately 1 200 g.
Frequently Asked Questions
1. What output does the 6AG1407-0KA02-7AA0 provide for the backplane bus?
It provides 5 V DC up to 10 A with no base load required and 24 V DC up to 1 A with idling-proof operation.
2. Which input voltages are supported?
Rated input values are 120 V DC, 230 V DC, 120 V AC, and 230 V AC.
3. What line frequency range does it support?
The rated line frequency is 50 Hz or 60 Hz, with a permissible range from 47 Hz to 63 Hz.
4. How long is the mains buffering time?
The stored energy time during mains or voltage failure is 20 ms, with mains buffering according to NAMUR recommendation.
5. What connection and mounting dimensions should be checked before inquiry?
The connection uses 3x 1.5 mm2 solid or stranded wire with end sleeve. The dimensions are 50 mm wide, 290 mm high, and 217 mm deep.