Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Rated output power (HO) | 45.00 kW | 60.00 hp |
| Rated output power (LO) | 55.00 kW | 75.00 hp |
| Input line voltage | 380 … 480 V ±10 % |
| Line frequency | 47 … 63 Hz |
| Output frequency for vector control | 0 … 200 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| Maximum output current | 180.00 A |
| Protection | IP20 / UL open type |
| Frame size | FSE |
| Integrated filter | Class A |
| Configuration exclusion | Without control unit and panel |
Key Features
- Power ratings: Rated output power: 45.00 kW (60.00 hp) HO and 55.00 kW (75.00 hp) LO.
- Overload capability: HO output: 200% for 3 s, 150% for 57 s, and 100% for 240 s at -20 … 50 °C. LO output: 150% for 3 s, 110% for 57 s, and 100% for 240 s at -20 … 40 °C.
- Input and output: Input and output: 3 AC. Line voltage: 380 … 480 V ±10 %. Line frequency: 47 … 63 Hz.
- Control frequencies: Output frequency: 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control. Pulse frequency: 4 kHz.
- Integrated functions and protection: Built-in Class A filter and braking chopper. Degree of protection: IP20 / UL open type.
- Connections and dimensions: Screw-type terminals are provided on the line side, motor end, DC link and PE connection. Dimensions: 551 mm × 275 mm × 237 mm; frame size FSE.
Frequently Asked Questions
1. What output power does the 6SL3210-1PE31-1AL0 support?
It has 45.00 kW (60.00 hp) rated output power in HO and 55.00 kW (75.00 hp) in LO.
2. What are the supported output frequency ranges?
Output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control.
3. What connections are provided?
It has screw-type terminals on the line side, motor end, DC link for a braking resistor, and PE connection.
4. What protection and mounting dimensions apply?
Protection is IP20 / UL open type; dimensions are 551 mm × 275 mm × 237 mm, with FSE frame size.
5. What is included in this configuration?
It is without control unit and panel.