Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Rated power (HO) | 37.00 kW | 50.00 hp |
| Rated power (LO) | 45.00 kW | 60.00 hp |
| Input line voltage | 380 … 480 V ±10 % |
| Input line frequency | 47 … 63 Hz |
| Output frequency for vector control | 0 … 200 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| Degree of protection | IP20 / UL open type |
| Frame size | FSE |
| Line-side connection | M6 bolt |
| Configuration exclusions | Without control unit and BOP |
Key Features
- Power module ratings: Rated power is 37.00 kW | 50.00 hp for high overload (HO) and 45.00 kW | 60.00 hp for light overload (LO).
- Input and output: Input and output each use 3 AC phases. Input line voltage is 380 … 480 V ±10 % at 47 … 63 Hz.
- Overload capability: HO output supports 200% for 3 s, 150% for 57 s, and 100% for 240 s at 0 … 50 °C. LO output supports 150% for 3 s, 110% for 57 s, and 100% for 240 s at 0 … 40 °C.
- Control output frequency: Output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control.
- Connections and cable length: Line-side and motor-end connections use M6 bolts with 10.00 … 50.00 mm2 (AWG 8 … AWG 1) conductors. Maximum motor cable length is 50 m shielded or 100 m unshielded.
- Protection and configuration: The module has IP20 / UL open type protection, FSE frame size, no integrated filter, and is supplied without a control unit and BOP.
Frequently Asked Questions
1. What is the rated output power of the 6SL3225-0BE33-7UA0?
Rated output power is 37.00 kW | 50.00 hp for high overload and 45.00 kW | 60.00 hp for light overload.
2. What input supply does this power module use?
It uses 3 AC input phases at 380 … 480 V ±10 % and 47 … 63 Hz.
3. Which output frequency ranges are supported?
The output frequency is 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control.
4. How is the module connected?
Line-side and motor-end connections use M6 bolts with 10.00 … 50.00 mm2 (AWG 8 … AWG 1) conductors.
5. What is excluded from this configuration?
It is without a control unit and BOP, and without an integrated filter.