Product image unavailable

1PH8284-1WD10-2AX1

Siemens 1PH8284-1WD10-2AX1 SIMOTICS M asynchronous motor with 150 kW rating, HTL 1024 S/R incremental encoder, IP55 protection and terminal-block connection. Request a model-specific quote.

Product Code
1PH8284-1WD10-2AX1
Weight
1200 kg
Lifecycle
Product cancellation
Availability
in stock
Lead Time
Confirmed with quotation
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Motor type SIMOTICS M compact asynchronous motor
Rated power at 1000 r/min 150 kW
Torque at 1000 r/min 1433 Nm
Current at 1000 r/min 315 A
Voltage at 1000 r/min 335 V
Rated power at 1150 r/min 170 kW
Rated power at 1350 r/min 200 kW
Encoder HTL 1024 S/R incremental encoder
Cooling Forced ventilation
Protection IP55 degree of protection
Mechanical design IM B3 (IMV6) with fitted-key shaft
Connection Terminal block with additional terminal box

Key Features

  1. Asynchronous motor ratings: 150 kW, 1433 Nm, 315 A at 335 V and 1150 r/min; 170 kW, 1414 Nm, 310 A at 400 V and 1350 r/min; 200 kW, 1416 Nm, 315 A at 460 V.
  2. Incremental encoder: HTL 1024 S/R incremental encoder, also identified as encoder HTL1024S/R.
  3. Cooling and protection: Forced ventilation with IP55 degree of protection.
  4. Mechanical design: Design IM B3 (IMV6), shaft with fitted key, half-key balancing, and standard bearing vibration severity grade A.
  5. Connection and signal details: Connection via terminal block with an additional terminal box; terminal box above, cable entry on the right, and signal connection NDE.
  6. Product lifecycle: Product cancellation.

Frequently Asked Questions

1. What motor ratings are specified for Siemens 1PH8284-1WD10-2AX1?

The motor has 150 kW, 1433 Nm, 315 A at 335 V and 1150 r/min; 170 kW, 1414 Nm, 310 A at 400 V and 1350 r/min; and 200 kW, 1416 Nm, 315 A at 460 V.

2. Which encoder is fitted to this SIMOTICS M motor?

It has an HTL 1024 S/R incremental encoder, also identified as encoder HTL1024S/R.

3. How is the motor connected?

It uses a terminal block with an additional terminal box. The terminal box is above, the cable entry is on the right, and the signal connection is NDE.

4. What cooling and protection details should be verified before inquiry?

The motor uses forced ventilation and has IP55 degree of protection.

Send Inquiry