Product image unavailable

1PH8137-1HD00-2BB1

Siemens 1PH8137-1HD00-2BB1 SIMOTICS M compact asynchronous motor with 17 kW at 1000 r/min, 43 A, 307 V, forced ventilation, and HTL 1024 S/R encoder. Request a model-specific quote.

Product Code
1PH8137-1HD00-2BB1
Weight
141 kg
Lifecycle
Product cancellation
Availability
in stock
Lead Time
Confirmed with quotation
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Motor_type SIMOTICS M compact asynchronous motor
Rated_output_at_1000_r_min 17 kW
Torque_at_1000_r_min 162 Nm
Current_at_1000_r_min 43 A
Voltage_at_1000_r_min 307 V
Encoder Incremental encoder HTL 1024 S/R
Ventilation Forced ventilation
Protection IP55
Design IM B3 (IM V5, IM V6)
Terminal_box Above; cable entry on the left
Signal_connection D-END

Key Features

  1. Motor ratings: At 1000 r/min: 17 kW, 162 Nm, 43 A, 307 V. Additional supplied ratings are 19.5 kW at 1150 r/min, 22 kW at 1350 r/min, and 24 kW at 1500 r/min.
  2. Encoder: Incremental encoder HTL 1024 S/R (encoder HTL1024S/R).
  3. Cooling and airflow: Forced ventilation; direction of air flow DE–> NDE.
  4. Protection and design: IP55 degree of protection and DESIGN IM B3 (IM V5, IM V6).
  5. Mechanical details: Shaft with fitted key, HALF-KEY BALANCING, bearing with fixed bearing, vibration severity grade R/A, and flange accuracy R.
  6. Connections and lifecycle: Terminal box above, cable entry on the left, signal connection D-END. Product cancellation.

Frequently Asked Questions

1. What motor ratings are supplied for 1PH8137-1HD00-2BB1?

The motor has 17 kW, 162 Nm, 43 A, and 307 V at 1000 r/min. Other supplied ratings are 19.5 kW at 1150 r/min, 22 kW at 1350 r/min, and 24 kW at 1500 r/min.

2. Which encoder is fitted to this motor?

It has an incremental encoder HTL 1024 S/R (encoder HTL1024S/R).

3. How is the motor ventilated and protected?

It has forced ventilation and IP55 degree of protection. The direction of air flow is DE–> NDE.

4. What are the motor design and connection details?

The design is IM B3 (IM V5, IM V6). The terminal box is above, the cable entry is on the left, and the signal connection is D-END.

Send Inquiry