Technical Summary

Parameter Value
Motor type SIMOTICS M compact asynchronous motor
Performance at 1500 r/min 160 kW, 1019 Nm, 340 A, 340 V
Performance at 1750 r/min 179 kW, 977 Nm, 330 A, 395 V
Performance at 2000 r/min 196 kW, 936 Nm, 325 A, 450 V
Encoder Incremental HTL 1024 S/R
Protection IP55 degree of protection
Mounting design IM B3 (IMB6, IMB7, IMB8, IMV6)
Ventilation Forced ventilation, air-flow direction DE–>NDE
Terminal box Above; cable entry on the right

Key Features

  1. Motor performance: 1500 r/min: 160 kW, 1019 Nm, 340 A, 340 V; 1750 r/min: 179 kW, 977 Nm, 330 A, 395 V; 2000 r/min: 196 kW, 936 Nm, 325 A, 450 V.
  2. Encoder: Incremental encoder HTL 1024 S/R (encoder HTL1024S/R).
  3. Temperature sensor: KTY 84-130 temperature sensor.
  4. Cooling and protection: Forced ventilation with air-flow direction DE–>NDE; IP55 degree of protection.
  5. Mounting design: DESIGN IM B3 (IMB6, IMB7, IMB8, IMV6).
  6. Shaft and connections: Shaft with fitted key and half-key balancing; standard bearing vibration severity grade R/A; shaft flange accuracy GR. R. Terminal box above, cable entry on the right, signal connection D-end.

Frequently Asked Questions

1. What motor performance values does the Siemens 1PH8228-1HF00-2BA1 provide?

At 1500 r/min it provides 160 kW, 1019 Nm, 340 A and 340 V; at 1750 r/min, 179 kW, 977 Nm, 330 A and 395 V; at 2000 r/min, 196 kW, 936 Nm, 325 A and 450 V.

2. Which encoder and temperature sensor are included?

It has an incremental HTL 1024 S/R encoder and a KTY 84-130 temperature sensor.

3. What protection and mounting designs does it have?

It has IP55 degree of protection and DESIGN IM B3 (IMB6, IMB7, IMB8, IMV6).

4. How are the terminal box and cable entry arranged?

The terminal box is above, the cable entry is on the right, and the signal connection is D-end.