Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Motor type | SIMOTICS M compact asynchronous motor |
| Rated speed and power | 400 r/min, 48 kW |
| Torque at 400 r/min | 1146 Nm |
| Current and voltage at 400 r/min | 132 A, 272 V |
| Additional speed and power | 500 r/min, 60 kW; 600 r/min, 72 kW |
| Encoder | Incremental encoder HTL 1024 S/R |
| Temperature sensor | KTY 84-130 |
| Ventilation | Forced ventilation, air-flow direction DE–>NDE |
| Protection | IP55 degree of protection |
| Mechanical design | IM B35 with flange A550 (IM V35) |
| Lifecycle | Product cancellation |
Key Features
- Compact asynchronous motor: SIMOTICS M compact asynchronous motor with 48 kW, 1146 Nm, 132 A and 272 V at 400 r/min.
- Additional speed ratings: At 500 r/min: 60 kW, 1146 Nm, 132 A and 340 V. At 600 r/min: 72 kW, 1146 Nm, 130 A and 410 V.
- Encoder and temperature sensor: Incremental encoder HTL 1024 S/R and temperature sensor KTY 84-130.
- Forced ventilation and protection: Forced ventilation with air-flow direction DE–>NDE and IP55 degree of protection.
- Mechanical design: Design IM B35 with flange A550 (IM V35), plain shaft without fitted key, and standard bearing.
- Connections and accuracy: Terminal box above, cable entry on the D-end, signal connection right, and shaft A.flange accuracy Gr. R.
Frequently Asked Questions
1. What motor ratings are specified for Siemens 1PH8228-1HB03-0BD1?
The motor has 48 kW, 1146 Nm, 132 A and 272 V at 400 r/min; 60 kW, 1146 Nm, 132 A and 340 V at 500 r/min; and 72 kW, 1146 Nm, 130 A and 410 V at 600 r/min.
2. Which feedback and temperature sensing devices are included?
It has an incremental encoder HTL 1024 S/R and a KTY 84-130 temperature sensor.
3. How is the motor ventilated and protected?
It has forced ventilation with air-flow direction DE–>NDE and IP55 degree of protection.
4. What mechanical and connection details should be verified before inquiry?
The design is IM B35 with flange A550 (IM V35), with a plain shaft without fitted key. The terminal box is above, the cable entry is on the D-end, and the signal connection is right.