1PH8184-1MF00-0AA1

Siemens 1PH8184-1MF00-0AA1 SIMOTICS M asynchronous motor with 51 kW, 325 Nm, 1500 r/min, IP55, and SIN/COS incremental encoder. Request a model-specific quote.

Product Code
1PH8184-1MF00-0AA1
Weight
350 kg
Lifecycle
Product cancellation
Availability
in stock
Lead Time
Confirmed with quotation
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Motor_type SIMOTICS M compact asynchronous motor
Rated_output_at_1500_r_min 51 kW
Torque_at_1500_r_min 325 Nm
Encoder SIN/COS 1 VPP incremental encoder, 2048 S/R, with C and D track
Protection IP55 degree of protection
Mounting_design IM B3 (IMB6, IMB7, IMB8, IMV6)
Ventilation Forced ventilation, air-flow direction DE–>NDE
Shaft Plain shaft without fitted key
Terminal_box Above
Cable_entry On the right
Signal_connection D-END
Lifecycle Product cancellation

Key Features

  1. Motor rating: 51 kW, 325 Nm, 116 A, 335 V at 1500 r/min.
  2. Additional motor ratings: 60 kW, 327 Nm, 120 A, 390 V at 1750 r/min; 68 kW, 325 Nm, 118 A, 405 V at 2000 r/min.
  3. Encoder: SIN/COS 1 VPP incremental encoder, 2048 S/R, with C and D track; encoder IC2048S/R.
  4. Ventilation and protection: Forced ventilation with air-flow direction DE–>NDE; IP55 degree of protection.
  5. Mechanical design: DESIGN IM B3, with IMB6, IMB7, IMB8, and IMV6; plain shaft without fitted key. Shaft A.FLANGE accuracy GR.N.
  6. Connections and bearing: Terminal box above, cable entry on the right, signal connection D-END, standard bearing, and vibration severity grade A.

Frequently Asked Questions

1. What motor ratings are available for Siemens 1PH8184-1MF00-0AA1?

The motor has 51 kW, 325 Nm, 116 A, 335 V at 1500 r/min; 60 kW, 327 Nm, 120 A, 390 V at 1750 r/min; and 68 kW, 325 Nm, 118 A, 405 V at 2000 r/min.

2. Which encoder is fitted to 1PH8184-1MF00-0AA1?

It has a SIN/COS 1 VPP incremental encoder with 2048 S/R and C and D track, encoder IC2048S/R.

3. What mounting and connection details should be verified before inquiry?

Verify the IM B3 design with IMB6, IMB7, IMB8, and IMV6 options, plain shaft without fitted key, terminal box above, cable entry on the right, and signal connection D-END.