Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Motor type | SIMOTICS M compact asynchronous motor |
| Speed and power configurations | 1500 r/min: 30 kW, 191 Nm, 71 A, 319 V; 1750 r/min: 34 kW, 186 Nm, 70 A, 366 V; 2000 r/min: 37 kW, 177 Nm, 68 A, 416 V; 2200 r/min: 40.7 kW, 177 Nm, 68 A, 456 V |
| Ventilation | Forced ventilation; air-flow direction NDE–> DE |
| Degree of protection | IP55 degree of protection INCREMENT |
| Encoder | HTL 1024 S/R |
| Temperature sensor | KTY84-130 |
| Design | IM B35; IM V15 and IM V35 |
| Shaft | Plain shaft without fitted key |
| Bearing | Standard; vibration severity grade R/A |
| Shaft and flange accuracy | R |
| Connection arrangement | Terminal box above; cable entry on the ND-end; signal connection left |
Key Features
- Power and speed configurations: 30 kW at 1500 r/min, 34 kW at 1750 r/min, 37 kW at 2000 r/min, or 40.7 kW at 2200 r/min, with the corresponding torque, current, and voltage values supplied for each configuration.
- HTL encoder and temperature sensor: HTL 1024 S/R encoder with KTY84-130 temperature sensor.
- Forced ventilation: Forced ventilation with air-flow direction from NDE to DE.
- Protection and mechanical design: IP55 degree of protection INCREMENT; IM B35 design, with IM V15 and IM V35 also specified.
- Shaft, bearing, and accuracy: Plain shaft without fitted key, standard bearing, vibration severity grade R/A, and shaft and flange accuracy R.
- Connection arrangement: Terminal box above, with cable entry on the ND-end and signal connection on the left.
Frequently Asked Questions
1. What motor configurations are supplied for Siemens 1PH8163-1HF13-0GC1?
The supplied configurations are 1500 r/min with 30 kW, 191 Nm, 71 A, and 319 V; 1750 r/min with 34 kW, 186 Nm, 70 A, and 366 V; 2000 r/min with 37 kW, 177 Nm, 68 A, and 416 V; or 2200 r/min with 40.7 kW, 177 Nm, 68 A, and 456 V.
2. Which encoder and temperature sensor does this motor have?
It has an HTL 1024 S/R encoder and a KTY84-130 temperature sensor.
3. How is the motor ventilated and protected?
It has forced ventilation with air flow from NDE to DE and an IP55 degree of protection INCREMENT.
4. What shaft and mounting design does the motor use?
It uses an IM B35 design and a plain shaft without a fitted key. IM V15 and IM V35 are also specified.
5. What connection arrangement should be verified before inquiry?
Verify the terminal box above, cable entry on the ND-end, and signal connection on the left.