| Parameter | Value |
|---|---|
| Motor type | SIMOTICS M compact asynchronous motor |
| Rated operating point | 1500 r/min, 22 kW, 140 Nm, 56 A, 308 V |
| Additional operating point | 1750 r/min, 25 kW, 136 Nm, 56 A, 352 V |
| Additional operating point 2 | 2000 r/min, 28 kW, 134 Nm, 55 A, 401 V |
| Additional operating point 3 | 2200 r/min, 30 kW, 130 Nm, 53 A, 440 V |
| Encoder | Incremental encoder HTL 2048 S/R |
| Temperature sensor | KTY 84-130 |
| Cooling | Forced ventilation; air flow direction NDE–> DE |
| Protection | IP55 degree of protection |
| Mechanical design | IM B3 (IM V5, IM V6); plain shaft WITHOUT FITTED KEY |
| Connections | Terminal box above; cable entry on the right; signal connection D-end |
Key Features
- Rated motor options: 1500 r/min: 22 kW, 140 Nm, 56 A, 308 V; 1750 r/min: 25 kW, 136 Nm, 56 A, 352 V; 2000 r/min: 28 kW, 134 Nm, 55 A, 401 V; 2200 r/min: 30 kW, 130 Nm, 53 A, 440 V.
- Encoder and temperature sensor: Incremental encoder HTL 2048 S/R and temperature sensor KTY 84-130.
- Cooling and protection: Forced ventilation with air flow direction NDE–> DE; IP55 degree of protection.
- Mechanical design: DESIGN IM B3 (IM V5, IM V6), plain shaft WITHOUT FITTED KEY, and standard bearing with fixed bearing.
- Connections and terminal box: Terminal box above, cable entry on the right, and signal connection on the D-end.
- Product lifecycle: Product cancellation.
Frequently Asked Questions
1. What motor ratings are provided for 1PH8137-1JF10-0BA1?
The source provides 1500 r/min at 22 kW, 140 Nm, 56 A and 308 V; 1750 r/min at 25 kW, 136 Nm, 56 A and 352 V; 2000 r/min at 28 kW, 134 Nm, 55 A and 401 V; and 2200 r/min at 30 kW, 130 Nm, 53 A and 440 V.
2. Which encoder and temperature sensor does the motor have?
It has an incremental encoder HTL 2048 S/R and a KTY 84-130 temperature sensor.
3. How is the motor cooled and protected?
It has forced ventilation with air flow direction NDE–> DE and IP55 degree of protection.
4. What are the shaft and mounting details?
The design is IM B3 (IM V5, IM V6), with a plain shaft WITHOUT FITTED KEY and a standard bearing with fixed bearing.
5. What should be verified before requesting a quote?
Verify the required speed, power, torque, current and voltage, plus the terminal-box position, cable-entry side and D-end signal connection.