Product Overview

Technical Summary

Parameter Value
Motor type SIMOTICS M compact asynchronous motor
Power and speed variants 15 kW at 1500 r/min; 17.5 kW at 1750 r/min; 20 kW at 2000 r/min; 22 kW at 2200 r/min
Torque 96 Nm
Current 34 A
Voltage variants 342 V; 392 V; 445 V; 480 V
Cooling Forced ventilation; air flow NDE–> DE
Protection IP55
Encoder Without encoder
Temperature sensor KTY 84-130
Mounting design IM B35 (IM V15, (IM V35)
Terminal box Above; cable entry on the right

Key Features

  1. Rated motor variants: 1500 r/min: 15 kW, 96 Nm, 34 A, 342 V; 1750 r/min: 17.5 kW, 96 Nm, 34 A, 392 V; 2000 r/min: 20 kW, 96 Nm, 34 A, 445 V; 2200 r/min: 22 kW, 96 Nm, 34 A, 480 V.
  2. Cooling and protection: Forced ventilation with air flow direction NDE–> DE and IP55 degree of protection.
  3. Encoder and temperature sensor: Without encoder; with temperature sensor KTY 84-130.
  4. Mechanical design: Design IM B35 (IM V15, (IM V35); shaft with fitted key; FULL-KEY BALANCING.
  5. Bearing and vibration: Bearing: standard. Vibration severity grade S/A.
  6. Connections and installation: Shaft A. Flange accuracy Gr. R. Terminal box above, cable entry on the right, and signal connection at the D-end.

Frequently Asked Questions

1. What motor ratings are available for 1PH8133-1AF13-1CA1?

The supplied ratings are 15 kW at 1500 r/min, 17.5 kW at 1750 r/min, 20 kW at 2000 r/min, and 22 kW at 2200 r/min. Each variant has 96 Nm and 34 A; the voltages are 342 V, 392 V, 445 V, and 480 V respectively.

2. Does this motor include an encoder?

It is without encoder and has a KTY 84-130 temperature sensor.

3. How is the motor cooled and protected?

It has forced ventilation with air flow direction NDE–> DE and IP55 degree of protection.

4. What are the mounting and connection details?

The design is IM B35 (IM V15, (IM V35). The shaft has a fitted key, the terminal box is above, the cable entry is on the right, and the signal connection is at the D-end.