Product image unavailable

1PH8107-1JF12-2BA1

Siemens SIMOTICS M compact asynchronous motor 1PH8107-1JF12-2BA1 has 9 kW at 1500 r/min, HTL encoder and KTY84-130 sensor. Request a model-specific quote.

Product Code
1PH8107-1JF12-2BA1
Weight
73 kg
Lifecycle
Product cancellation
Availability
in stock
Lead Time
Confirmed with quotation
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Motor type SIMOTICS M compact asynchronous motor
Performance points 1500 r/min: 9 kW, 57 Nm, 23.5 A, 330 V; 1750 r/min: 10 kW, 55 Nm, 22 A, 380 V; 2000 r/min: 11 kW, 53 Nm, 21.5 A, 428 V; 2200 r/min: 12.1 kW, 53 Nm, 21.5 A, 470 V
Encoder HTL 2048 S/R
Temperature sensor KTY84-130
Ventilation Forced ventilation; air flow direction NDE–> DE
Protection IP55 degree of protection INCREMENT
Mounting IM B5 (IMV 1,IM V3)
Shaft Fitted key; HALF-KEY BALANCING
Bearing Standard with fixed bearing
Terminal box Above; cable entry on the right
Lifecycle Product cancellation

Key Features

  1. Performance points: 1500 r/min: 9 kW, 57 Nm, 23.5 A, 330 V; 1750 r/min: 10 kW, 55 Nm, 22 A, 380 V; 2000 r/min: 11 kW, 53 Nm, 21.5 A, 428 V; 2200 r/min: 12.1 kW, 53 Nm, 21.5 A, 470 V.
  2. Encoder and sensor: HTL 2048 S/R encoder and KTY84-130 temperature sensor.
  3. Ventilation and protection: Forced ventilation with air flow direction NDE–> DE and IP55 degree of protection INCREMENT.
  4. Mounting and shaft: Design IM B5 (IMV 1,IM V3); shaft has a fitted key and HALF-KEY BALANCING.
  5. Bearing and accuracy: Standard bearing with fixed bearing; vibration severity grade R/A; shaft and flange accuracy R.
  6. Terminal box and signal connection: Terminal box above, cable entry on the right, signal connection D-END.

Frequently Asked Questions

1. What performance points does 1PH8107-1JF12-2BA1 have?

1500 r/min: 9 kW, 57 Nm, 23.5 A, 330 V; 1750 r/min: 10 kW, 55 Nm, 22 A, 380 V; 2000 r/min: 11 kW, 53 Nm, 21.5 A, 428 V; 2200 r/min: 12.1 kW, 53 Nm, 21.5 A, 470 V.

2. Which encoder and temperature sensor are included?

It has an HTL 2048 S/R encoder and KTY84-130 temperature sensor.

3. How is the motor mounted and ventilated?

It has IM B5 (IMV 1,IM V3) design and forced ventilation with air flow direction NDE–> DE.

4. Where are the terminal box and cable entry located?

The terminal box is above and the cable entry is on the right; signal connection is D-END.

Send Inquiry