Product Overview

Technical Summary

Parameter Value
Motor type SIMOTICS M compact asynchronous motor
Performance points 1500 r/min: 5.5 kW, 35 Nm, 13.5 A, 368 V; 1750 r/min: 6.3 kW, 34 Nm, 13.1 A, 412 V; 2000 r/min: 7 kW, 33 Nm, 12.7 A, 460 V; 2200 r/min: 7.7 kW, 33 Nm, 12.7 A, 480 V
Cooling Forced ventilation
Encoder HTL 1024 S/R Encoder
Temperature sensor KTY84-130
Protection IP55
Mounting design IM B5 (IMV 1,IM V3)
Terminal box Above; cable entry on the right; signal connection D-end

Key Features

  1. Performance points: 1500 r/min: 5.5 kW, 35 Nm, 13.5 A, 368 V; 1750 r/min: 6.3 kW, 34 Nm, 13.1 A, 412 V; 2000 r/min: 7 kW, 33 Nm, 12.7 A, 460 V; 2200 r/min: 7.7 kW, 33 Nm, 12.7 A, 480 V.
  2. Encoder and temperature sensor: HTL 1024 S/R Encoder with KTY84-130 temperature sensor.
  3. Cooling and air direction: Forced ventilation; air-flow direction NDE–> DE.
  4. Mechanical design: IM B5 design (IMV 1,IM V3) with fitted key and half-key balancing.
  5. Protection and bearing: IP55 degree of protection; standard bearing with fixed bearing.
  6. Connections and accuracy: Terminal box above, cable entry on the right, signal connection D-end; vibration severity grade R/A and shaft and flange accuracy R.

Frequently Asked Questions

1. What motor performance points are provided for 1PH8103-1HF12-2BA1?

The source lists 1500 r/min: 5.5 kW, 35 Nm, 13.5 A, 368 V; 1750 r/min: 6.3 kW, 34 Nm, 13.1 A, 412 V; 2000 r/min: 7 kW, 33 Nm, 12.7 A, 460 V; and 2200 r/min: 7.7 kW, 33 Nm, 12.7 A, 480 V.

2. Which feedback and temperature-sensing components does it have?

It has an HTL 1024 S/R Encoder and a KTY84-130 temperature sensor.

3. What mounting design and cable-entry arrangement does it use?

It uses IM B5 design (IMV 1,IM V3). The terminal box is above, and the cable entry is on the right.

4. What protection and cooling details should be verified before inquiry?

The motor has IP55 protection and forced ventilation, with air-flow direction NDE–> DE.