6AG1326-2BF41-2AY0

Siemens 6AG1326-2BF41-2AY0 SIPLUS S7-300 F-DQ module with 8 fail-safe 24 V DC outputs, 2 A rated output current, and diagnostic functions. Request a model-specific quote.

Product Code
6AG1326-2BF41-2AY0
Dimensions
14.9 × 13.2 × 8.9 cm
Weight
0.486 kg
Lifecycle
Product cancellation
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Digital output channels 8 F-DQ
Rated supply voltage 24 V; 1L+
Rated load voltage 24 V; 2L+, 3L+
Rated output current for signal "1" 2 A
Output current range, 0 to 40 °C 7 mA to 2 A; with horizontal installation, 1 A with vertical installation
Switching frequency, resistive load 30 Hz, max.
Switching frequency, inductive load 2 Hz, max.
Diagnostic alarm Yes; parameterizable
Potential separation Between channels; between channels and backplane bus; between channels and the electronics power supply
Isolation test 500V AC for 1 min (internal voltage limiting to ±120V)
Product lifecycle Product cancellation

Applications

  1. Fail-safe digital output control: Controls digital output signals using F-DQ sinking-sourcing outputs with fail-safe operation.

Key Features

  1. Fail-safe digital outputs: 8 F-DQ digital outputs with sinking-sourcing operation up to category 4 (EN 954-1) and SIL 3 (IEC 61508).
  2. Supply and load voltage: Rated supply voltage: 24 V; 1L+. Rated load voltage: 24 V; 2L+, 3L+.
  3. Output current: Rated output current for signal "1": 2 A. Permissible range for 0 to 40 °C: 7 mA to 2 A with horizontal installation, and 1 A with vertical installation.
  4. Diagnostics and protection: Short-circuit protection, parameterizable diagnostic alarm, readable diagnostic information, fail-safe operation indication, and red SF group error LED.
  5. Electrical isolation: Digital outputs have potential separation between channels, between channels and the backplane bus, and between channels and the electronics power supply.
  6. Timing and connection limits: Maximum switching frequency is 30 Hz with resistive load, 2 Hz with inductive load, and 10 Hz with lamp load. Maximum cable length is 200 m.

Frequently Asked Questions

1. How many digital outputs does the 6AG1326-2BF41-2AY0 have?

It has 8 F-DQ digital outputs.

2. What output current does this module provide?

The rated output current for signal "1" is 2 A. From 0 to 40 °C, the permissible range is 7 mA to 2 A with horizontal installation, and 1 A with vertical installation.

3. What diagnostics are available?

It has a parameterizable diagnostic alarm, readable diagnostic information, fail-safe operation indication, and a red SF group error LED.

4. What cable length is supported?

The maximum cable length is 200 m for shielded and unshielded cable; 200 m applies for SIL 3, AK 6, Cat 4 with shielded cable.

5. Is the module protected against short circuits?

Yes, the digital outputs have short-circuit protection.

Send Inquiry