Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Product type | Bus cable |
| Connection | One preassembled 4-pin M8 plug; 180° cable outlet |
| Cable cores | 4 |
| Cable sheath | PUR |
| Protection suitability | IP65/67 |
| Minimum assembly temperature | -30 °C |
| Maximum assembly temperature | 80 °C |
| Minimum storage/transport temperature | -40 °C |
| Maximum storage/transport temperature | 80 °C |
| Minimum single-bend radius | 20 mm |
| Minimum multiple-bend radius | 40 mm |
Applications
- ET-CONNECTION node connection: Connects ET-CONNECTION nodes, e.g. SIMATIC ET 200AL, using an M8 bus connection.
Key Features
- Bus cable and connection: Bus cable for ET connection M8 with one preassembled 4-pin M8 plug and a 180° cable outlet.
- Cable construction: Flexible 4-core shielded cable with PUR sheath, PE core insulation, and cable designation 2Y(ST)C11Y 2x2x0.5/1.0-100-GN.
- Cable dimensions: Cable length: 5 m; outer diameter of inner conductor: 0.5 mm; outer diameter of core insulation: 1 mm; outer diameter of cable sheath: 5 mm.
- Bending specifications: Minimum permissible bending radius: 20 mm for a single bend and 40 mm for multiple bends. Continuous bending radius: 100 mm.
- Protection and suitability: Suitable for connecting ET-CONNECTION nodes, such as SIMATIC ET 200AL, in IP65/67 protection.
- Material properties: The cable sheath is green, halogen-free, and silicone-free. Data-core insulation colors are white / yellow / blue / orange.
Frequently Asked Questions
1. What connection does Siemens 6ES7194-2MH50-0AC0 provide?
It provides a bus cable for ET connection M8 with one preassembled 4-pin M8 plug and a 180° cable outlet.
2. What is the cable length and core count?
The cable length is 5 m and the cable has 4 electrical cores.
3. What protection suitability is specified for this cable?
It is suitable for connecting ET-CONNECTION nodes, such as SIMATIC ET 200AL, in IP65/67 protection.