6SL3211-1PB21-0AL0

Siemens SINAMICS Power Module 6SL3211-1PB21-0AL0 with Class A filter and braking chopper, 200-240 V 1/3AC, IP20-PT. Request a model-specific quote.

Product Code
6SL3211-1PB21-0AL0
Dimensions
20 × 20.5 × 38.5 cm
Weight
3.9 kg
Lifecycle
Product cancellation
Availability
in stock
Lead Time
Confirmed with quotation

Product Tags

Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Module SINAMICS Power Module PM240-2
Supply 200-240 V 1/3AC+10/-10%, 47-63Hz
High overload power 1.5 kW at 200% 3 s, 150% 57 s, 100% 240 s; ambient temperature -10 to +50 °C
Low overload power 2.2 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature -10 to +40 °C
Integrated components Class A filter and braking chopper
Degree of protection IP20-PT
Included equipment Without Control Unit and operation panel
Firmware status Released as of CU Firmware version V4.6
Lifecycle Product cancellation

Key Features

  1. Power module type: SINAMICS Power Module PM240-2 with an integrated Class A filter and integrated braking chopper.
  2. Supply: 200-240 V 1/3AC+10/-10% at 47-63Hz.
  3. High overload power: 1.5 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s; ambient temperature -10 to +50 °C.
  4. Low overload power: 2.2 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s; ambient temperature -10 to +40 °C.
  5. Form factor and protection: FSB dimensions: 345 x 154 x 171 mm (HxWxD); degree of protection IP20-PT.
  6. Configuration and lifecycle: Without Control Unit and operation panel; Product cancellation. Released as of CU Firmware version V4.6.

Frequently Asked Questions

1. What is the function of 6SL3211-1PB21-0AL0?

It is a SINAMICS Power Module PM240-2 with an integrated Class A filter and braking chopper.

2. What supply does this Power Module use?

Supply is 200-240 V 1/3AC+10/-10% at 47-63Hz.

3. What are the high and low overload power ratings?

High overload power is 1.5 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s at -10 to +50 °C. Low overload power is 2.2 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s at -10 to +40 °C.

4. What is included in this configuration?

It is without a Control Unit and operation panel.

5. What are the dimensions and protection degree?

The FSB dimensions are 345 x 154 x 171 mm (HxWxD), with degree of protection IP20-PT.

Send Inquiry