1FK7064-4CH71-1PH2

Siemens 1FK7064-4CH71-1PH2 SIMOTICS S synchronous motor with 2.4 kW power, 600 VDC, resolver and IP65 protection. Request a model-specific quote.

Product Code
1FK7064-4CH71-1PH2
Weight
15.8 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Power 2.4 kW
DC link voltage 600 VDC
Rated speed 4,500 rpm (100 K)
Rated torque 5.0 Nm (100 K)
Maximum torque 32.0 Nm
Feedback Resolver R14DQ, 14 bits, resolution 16384
Mounting design IM B5 (IM V1, IM V3)
Cooling Natural cooling
Connector size M23
Degree of protection IP65 and DE flange IP67
Holding brake Permanent-magnet brake, 13.0 Nm holding torque
Temperature monitoring Pt1000 temperature sensor

Key Features

  1. Motor performance: Rated speed: 4,500 rpm (100 K); rated torque: 5.0 Nm (100 K); maximum torque: 32.0 Nm.
  2. Resolver feedback: Resolver R14DQ: resolver 14 bits with resolution 16384 and internal 2-pole design.
  3. Mounting and cooling: Natural cooling; design acc. to Code I: IM B5 (IM V1, IM V3); plain shaft.
  4. Connectors and protection: Rotatable connectors for signals and power; M23 connector size; IP65 and DE flange IP67.
  5. Holding brake: Permanent-magnet brake with holding torque 13.0 Nm and DC 24 V ± 10 % power supply.
  6. Temperature monitoring: Pt1000 temperature sensor.

Frequently Asked Questions

1. What is the power and rated speed of the 1FK7064-4CH71-1PH2?

Power is 2.4 kW and rated speed is 4,500 rpm (100 K).

2. Which feedback system does this motor have?

It has a Resolver R14DQ system with 14 bits, resolution 16384, and an internal 2-pole design.

3. How is the motor mounted and cooled?

It has natural cooling and an IM B5 design (IM V1, IM V3) with a plain shaft.

4. What connectors and protection does it provide?

It has rotatable signal and power connectors, M23 connector size, IP65 protection, and IP67 protection at the DE flange.

5. What holding-brake details should be verified before inquiry?

The permanent-magnet brake has 13.0 Nm holding torque and requires DC 24 V ± 10 % power supply.