1FK7064-4CF71-1UA2

Siemens 1FK7064-4CF71-1UA2 SIMOTICS S synchronous motor with 2.5 kW optimum power, 3,000 rpm speed, Resolver R15DQ and DRIVE-CLiQ interface. Request a model-specific quote.

Product Code
1FK7064-4CF71-1UA2
Weight
15.402 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Optimum power 2.5 kW
Optimum speed 3,000 rpm
Rated torque (100 K) 8.0 Nm
Rated current 7.6 A
Maximum torque 32.0 Nm
Maximum current 33.0 A
Encoder system Resolver R15DQ: resolver 15 bits (resolution 32768, internal multi-pole)
Electrical connectors Connectors for signals and power rotatable
Cooling Natural cooling
Degree of protection IP65 and DE flange IP67
Design acc. to Code I IM B5 (IM V1, IM V3)
Holding brake without holding brake

Key Features

  1. Performance: Optimum power: 2.5 kW; optimum speed: 3,000 rpm; rated torque (100 K): 8.0 Nm.
  2. Electrical data: Rated current: 7.6 A; maximum current: 33.0 A; rated inverter current: 18 A.
  3. Encoder system: Resolver R15DQ: resolver 15 bits with resolution 32768 and internal multi-pole design.
  4. Interfaces and connectors: DRIVE-CLiQ interface; M23 electrical connectors for signals and power, rotatable.
  5. Cooling and protection: Natural cooling; degree of protection IP65 and DE flange IP67.
  6. Mechanical configuration: IM B5 (IM V1, IM V3) design, rotatable power connector, feather key shaft end, and without holding brake.

Frequently Asked Questions

1. What type of motor is the Siemens 1FK7064-4CF71-1UA2?

It is a permanent-magnet synchronous motor with High Dynamic motor type.

2. What encoder system does this motor use?

It uses a Resolver R15DQ: resolver 15 bits with resolution 32768 and internal multi-pole design.

3. Which connectors and interface are provided?

It has an M23 rotatable electrical connector for signals and power and a DRIVE-CLiQ interface.

4. What are the cooling and protection details?

Cooling is natural. The degree of protection is IP65, with DE flange IP67.

Send Inquiry