Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Optimum power | 2.0 kW |
| Rated speed (100 K) | 4,500 rpm |
| Rated torque (100 K) | 4.3 Nm |
| Rated current | 6.2 A |
| Encoder system | Absolute single-turn 24-bit Encoder AS24DQI with DRIVE-CLiQ interface |
| Maximum permissible speed (mech.) | 7,500 rpm |
| Maximum torque | 17.3 Nm |
| Holding torque | 13.0 Nm |
| Power supply voltage | DC 24 V ± 10 % |
| Design | IM B5 (IM V1, IM V3) |
| Degree of protection | IP65 and DE flange IP67 |
Key Features
- Motor performance: Optimum power: 2.0 kW; rated speed (100 K): 4,500 rpm; rated torque (100 K): 4.3 Nm.
- Encoder interface: Absolute single-turn 24-bit Encoder AS24DQI with DRIVE-CLiQ interface.
- Electrical data: Rated current: 6.2 A; maximum current: 26.5 A; winding resistance at 20o C: 0.35 Ω.
- Brake and supply: Permanent-magnet holding brake with 13.0 Nm holding torque and DC 24 V ± 10 % power supply voltage.
- Mounting and connectors: Design: IM B5 (IM V1, IM V3); M23 connector size; electrical connectors for signals and power are rotatable.
- Cooling and protection: Natural cooling; degree of protection: IP65 and DE flange IP67.
Frequently Asked Questions
1. What motor type is the 1FK7061-4CH71-1BH2?
It is a permanent-magnet synchronous motor, also identified as High Dynamic.
2. Which Encoder is installed?
It has an absolute single-turn 24-bit Encoder AS24DQI with DRIVE-CLiQ interface.
3. What are the motor speed and torque limits?
The maximum permissible speed is 7,500 rpm for mechanical and inverter operation, and the maximum torque is 17.3 Nm.
4. What mounting and connector details should be verified?
The design is IM B5 (IM V1, IM V3), the connector size is M23, and the signal and power connectors are rotatable.