Technical Summary
| Parameter | Value |
|---|---|
| Power rating | PN=2kW |
| DC voltage | UDC=600V |
| Torque | M0=6.4Nm (100K) |
| Speed | NN=4500rpm |
| Encoder | Incremental Encoder SIN/COS 1VPP;2048 S/R W. C-AND D-SPUR (ENCODER IC2048S/R) |
| Mounting and cooling | Naturally cooled; FRAME SIZE IMB 5 (IM V1, IM V3), FLANGE 1 |
| Protection | IP65 DE flange IP67 |
| Brake | Without holding brake |
Key Features
- Motor ratings: PN=2kW, UDC=600V, M0=6.4Nm (100K), and NN=4500rpm.
- Encoder: Incremental Encoder SIN/COS 1VPP;2048 S/R W. C-AND D-SPUR (ENCODER IC2048S/R).
- Mounting and cooling: Naturally cooled, with FRAME SIZE IMB 5 (IM V1, IM V3) and FLANGE 1.
- Temperature sensor and connector: WITH KTY TEMPERATURESENSOR and a rotatable POWER CONNECTOR.
- Shaft and tolerance: Shaft with fitted key and tolerance N.
- Protection and brake configuration: Degree of protection IP65 DE flange IP67; without holding brake.
Frequently Asked Questions
1. What are the ratings of the 1FK7061-4CH71-1AA2 motor?
PN=2kW, UDC=600V, M0=6.4Nm (100K), and NN=4500rpm.
2. Which encoder does this motor have?
It has an incremental Encoder SIN/COS 1VPP;2048 S/R W. C-AND D-SPUR (ENCODER IC2048S/R).
3. How is the motor mounted and cooled?
It is naturally cooled and has FRAME SIZE IMB 5 (IM V1, IM V3) with FLANGE 1.
4. Does the configuration include a holding brake?
It is without holding brake.