1FK7043-4CH71-1CH2 SIMOTICS S synchronous motor with 1.2 kW optimum power, 4,500 rpm speed and absolute 24-bit + 12-bit multiturn Encoder AM24DQI. Request a model-specific quote.

Product Code
1FK7043-4CH71-1CH2
Weight
6.3 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
Request Current Quote

Current status: in stock. Price, condition, lead time and warranty are confirmed in the quotation.

Product Overview

Technical Summary

Parameter Value
Motor type Permanent-magnet synchronous motor; High Dynamic
Optimum power 1.2 kW
Rated speed (100 K) 4,500 rpm
Rated torque (100 K) 2.6 Nm
Encoder system Absolute Encoder AM24DQI: 24 bits + 12 bits multiturn
Encoder interface DRIVE-CLiQ
Electrical connector size M23
Cooling Natural cooling
Installation design IM B5 (IM V1, IM V3)
Degree of protection IP65 and DE flange IP67
Holding torque 4.0 Nm
Holding brake power supply voltage DC 24 V ± 10 %

Key Features

  1. Motor performance: Optimum power: 1.2 kW; rated speed (100 K): 4,500 rpm; rated torque (100 K): 2.6 Nm.
  2. Encoder feedback: Absolute Encoder AM24DQI: 24 bits with resolution 16777216 and encoder-internal 2048 S/R, plus 12 bits multiturn with a traversing range of 4096 revolutions.
  3. Drive interface and connectors: DRIVE-CLiQ interface; M23 electrical connectors for signals and power are rotatable.
  4. Installation and cooling: Natural cooling; design acc. to Code I: IM B5 (IM V1, IM V3); plain shaft with tolerance N.
  5. Protection and brake: Degree of protection: IP65 and DE flange IP67; permanent-magnet holding brake with 4.0 Nm holding torque and DC 24 V ± 10 % power supply voltage.

Frequently Asked Questions

1. What encoder system does the 1FK7043-4CH71-1CH2 have?

It has an absolute Encoder AM24DQI with 24 bits, resolution 16777216, encoder-internal 2048 S/R, and 12 bits multiturn with a traversing range of 4096 revolutions.

2. What connectors and interface does this motor provide?

It has a DRIVE-CLiQ interface and rotatable M23 connectors for signals and power.

3. What holding-brake data should be verified for quotation?

The permanent-magnet holding brake has 4.0 Nm holding torque, DC 24 V ± 10 % power supply voltage, 0.5 A coil current, 70 ms opening time, and 30 ms closing time.

Send Inquiry