Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Product type | SIMATIC MODBUS/TCP PN Red software |
| System context | For S7-400 PN-(H) systems |
| Communication roles | Modbus server and Modbus client |
| User data per job, max. | 250 byte |
| Implemented function codes | 01, 02, 03, 04, 05, 06, 15, 16 |
| Redundancy capability | Yes; suitable for configuring H systems |
| STEP 7 TIA Portal version | V13 |
| STEP 7 version | STEP 7 V5.5 SP2 HF1 or higher |
| License | Single license (EL) |
| Delivery | On CD-ROM |
Applications
- Modbus server and client communication: The software provides communication as a Modbus server and as a Modbus client.
- Redundant H-system configuration: The redundancy capability is suitable for configuring H systems.
Key Features
- Modbus communication: Communication is supported as both a Modbus server and a Modbus client.
- Redundancy capability: Redundancy capability is available and suitable for configuring H systems.
- User data capacity: User data per job is up to 250 byte.
- Supported function codes: Implemented function codes are 01, 02, 03, 04, 05, 06, 15, 16.
- Engineering software support: STEP 7 TIA Portal is configurable/integrated from version V13; STEP 7 is configurable/integrated from STEP 7 V5.5 SP2 HF1 or higher.
- License and delivery: The product has a single license (EL) and is supplied on CD-ROM.
Frequently Asked Questions
1. What communication roles does 6AV6676-6MB10-0AX0 support?
It supports communication as a Modbus server and as a Modbus client.
2. How much user data can be transferred per job?
User data per job is up to 250 byte.
3. Which Modbus function codes are implemented?
Implemented function codes are 01, 02, 03, 04, 05, 06, 15, 16.
4. What is included with the license?
It has a single license (EL) and is supplied on CD-ROM.