Product Overview
Technical Summary
| Parameter | Value |
|---|---|
| Product type | SIMOTICS M compact asynchronous motor |
| Rated point at 400 r/min | 16.3 kW, 389 Nm, 49 A, 271 V |
| Rated point at 500 r/min | 20.5 kW, 392 Nm, 49 A, 335 V |
| Rated point at 600 r/min | 25 kW, 398 Nm, 49 A, 410 V |
| Encoder | Incremental encoder HTL 1024 S/R |
| Ventilation | Forced ventilation, air-flow direction DE–>NDE |
| Protection | IP55 degree of protection |
| Mounting | IM B5 with A450 flange (IM V3) |
| Connection | Terminal block with additional terminal box |
| Temperature sensor | Pt1000 |
| Terminal-box position | Above; cable entry on the right |
Key Features
- Rated motor points: 400 r/min: 16.3 kW, 389 Nm, 49 A, 271 V; 500 r/min: 20.5 kW, 392 Nm, 49 A, 335 V; 600 r/min: 25 kW, 398 Nm, 49 A, 410 V.
- Incremental encoder: HTL 1024 S/R incremental encoder, also identified as encoder HTL1024S/R.
- Cooling and protection: Forced ventilation with air-flow direction DE–>NDE and IP55 degree of protection.
- Mounting and shaft: IM B5 design with A450 flange (IM V3); shaft with fitted key and full-key balancing.
- Connections: Connection via terminal block with an additional terminal box; terminal box above, cable entry on the right, signal connection D-end.
- Temperature sensing: Pt1000 temperature sensor.
Frequently Asked Questions
1. What motor ratings are listed for 1PH8184-1WB02-1BA2?
The listed points are 16.3 kW at 400 r/min, 20.5 kW at 500 r/min, and 25 kW at 600 r/min, with the corresponding torque, current, and voltage values shown in the specification.
2. Which encoder does this motor have?
It has an HTL 1024 S/R incremental encoder, also identified as encoder HTL1024S/R.
3. How is the motor connected?
It is connected via a terminal block with an additional terminal box. The terminal box is above, the cable entry is on the right, and the signal connection is D-end.
4. What mounting and protection details should be verified?
The motor has IM B5 mounting with an A450 flange (IM V3), forced ventilation in the DE–>NDE direction, and IP55 degree of protection.