| Parameter | Value |
|---|---|
| Motor type | SIMOTICS M compact asynchronous motor |
| Rated speed and power | 1500 r/min, 18.5 kW at 330 V |
| Additional rating | 1750 r/min, 21.5 kW at 383 V |
| Additional rating 2 | 2000 r/min, 24 kW at 434 V |
| Additional rating 3 | 2200 r/min, 26.4 kW at 468 V |
| Torque | 118 Nm at 1500 r/min; 117 Nm at 1750 r/min; 115 Nm at 2000 r/min and 2200 r/min |
| Current | 43 A at the listed ratings |
| Encoder | Incremental encoder HTL 1024 S/R |
| Temperature sensor | KTY 84-130 |
| Cooling | Forced ventilation; air flow DE–> NDE |
| Protection | IP55 degree of protection |
| Connection and mounting | Terminal box above; cable entry on the right; DESIGN IM B3, IM V5, IM V6 |
Key Features
- Speed-dependent motor ratings: The motor provides 18.5 kW, 118 Nm and 43 A at 1500 r/min and 330 V; 21.5 kW, 117 Nm and 43 A at 1750 r/min and 383 V; 24 kW, 115 Nm and 43 A at 2000 r/min and 434 V; or 26.4 kW, 115 Nm and 43 A at 2200 r/min and 468 V.
- Incremental encoder: Incremental encoder HTL 1024 S/R is fitted for signal feedback.
- Temperature sensor: The motor includes a KTY 84-130 temperature sensor.
- Forced ventilation: Cooling is provided by forced ventilation, with air flow from DE to NDE.
- Mechanical design and mounting: The motor has DESIGN IM B3, with IM V5 and IM V6 options, and a shaft with fitted key.
- Protection and connections: It has IP55 degree of protection, a terminal box above, cable entry on the right, and signal connection at the D-end.
Frequently Asked Questions
1. What motor is Siemens 1PH8135-1HF00-2BA1?
It is a SIMOTICS M compact asynchronous motor with forced ventilation, an incremental HTL 1024 S/R encoder, and a KTY 84-130 temperature sensor.
2. What ratings does the motor provide?
It provides 18.5 kW at 1500 r/min and 330 V, 21.5 kW at 1750 r/min and 383 V, 24 kW at 2000 r/min and 434 V, or 26.4 kW at 2200 r/min and 468 V; the listed current is 43 A.
3. What protection and cooling does it have?
The motor has IP55 degree of protection and forced ventilation, with air flow from DE to NDE.
4. How are the motor connections arranged?
The terminal box is above, cable entry is on the right, and the signal connection is at the D-end.